Back to top
Send SMS
+918045475874
Most Popular Products
Trust Stamp
Product Showcase

UDC3200 Universal Digital Controller

UDC3200 Universal Digital Controller

Product Details:

  • Product Type digital controller
  • Material Standard
  • Measuring Voltage Range 120 Vac or 240 Vac or 30 Vdc
  • Frequency (MHz) 50/60 Hertz (HZ)
  • Protection System Standard
  • Size 1/4 DIN
  • Warranty 1 Year
1 INR/Unit
X

Price And Quantity

  • 1 Unit
  • 1 INR/Unit

Product Specifications

  • digital controller
  • 1 Year
  • Standard
  • 50/60 Hertz (HZ)
  • 120 Vac or 240 Vac or 30 Vdc
  • Standard
  • 1/4 DIN

Trade Information

  • Telegraphic Transfer (T/T)
  • Gujarat

Product Description

Features:
  • 2 Universal Analog Inputs
  • Fast scanning rate (166ms)
  • Up to 5 Analog Output Types
  • Math Functions
  • Ethernet and Modbus communication
  • Infrared PC & Pocket PC configuration
  • NEMA4X and IP66 front face protection
  • Multilanguage prompts
  • Jumper free configuration
  • Easily Field Upgradable
  • Bright, dual displays with multi-language prompts (in English, French, German,
  • Spanish, or Italian) make the operator interface easy to read, understand, and operate
  • Simple keystrokes let you set operating parameters that meet your process control needs

Math Functions:
  • Algorithm-A pre-configured algorithm is available for easy
  • implementation.
  • This includes the capability of using a Ratio and Bias with any input.
  • You can select from the following menu: Feedforward Summer-Uses either input, followed by a Ratio/Bias calculation, summed directly with the computed PID output value to provide a resultant output to the final control element (standard feature).
  • Weighted Average Computes the weighted average of a PV or SP for the control algorithm from two inputs (standard feature)
  • Feedforward Multiplier-Uses any input, multiplied by the calculated PID output to provide a resultant output which is sent to the final control element (standard feature).
  • Summer/Subtractor-Will add or subtract inputs with the result used as the derived PV
  • Multiplier/Divider-Uses the analog inputs to calculate a derived PV
  • Available with or without Square Root
  • Input High/Low Select-Specifies the PV input as the higher or lower of the two inputs
Digital Inputs:
  • Two isolated digital inputs are provided for remote dry contact closure to select one of the following actions: Manual control mode
  • Local setpoint 1
  • Local setpoint 2
  • Local setpoint 3
  • Direct controller action
  • Hold SP Ramp/Program
  • Select PID set 2
  • PV = Input 2
  • ReRun - SP Ramp/Program
  • Run - SP Ramp/Program
  • External program reset
  • Disable PID integral action
  • Manual mode, failsafe output
  • Disable keyboard
  • Output 1 = Fixed value
  • Start Timer
  • Auto/Manual Station
  • Initiate Tuning
  • Initiate PV Hot Start
  • Output 1 tracks Input 2
  • To Remote Setpoint
  • PID reset feedback via Input 2
  • Purge
  • Low Fire
  • To Latching Manual Mode.
  • Also, the digital inputs can allow one of the following selections to be combined with one of the above selections: Select PID set 2
  • Direct controller action
  • Local setpoint 2 or Local setpoint 1
  • Disable Accutune
  • To Run – SP Ramp/Program
  • The 2nd Current Output and the 2nd
  • Digital Input are mutually exclusive
  • Selection is made via a keyboard entry

SHINE CLUSTER INDUSTRIES

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.