Automatic Burner Control Unit

Product Details:
- Product Type burner controllers
- Material Standard
- Operating Temperature -40 to +80 Celsius (oC)
- Protection System Standard
- Size Standard
- Weight 610 Grams (g)
- Warranty 1 Year
1 INR/Unit
X
Price And Quantity
- 1 INR/Unit
- 1 Unit
Product Specifications
- 1 Year
- Standard
- 610 Grams (g)
- burner controllers
- Standard
- -40 to +80 Celsius (oC)
- Standard
Trade Information
- Telegraphic Transfer (T/T)
- Standard
- Asia
- Gujarat
Product Description
Features:- For directly ignited burners of unlimited capacity in continuous operation pursuant to EN 746-2
- Continuous self-testing for faults
- Immediate fault lock-out or restart following flame failure available as a switchable function
- Flame control with UV sensor or ionization sensor
- Diverse installation possibilities via holes or snap mechanism for DIN rail
- Space-saving installation on site with IFD 258..I with integrated ignition
- Display for program status and flame signal intensity
- Automatic burner control unit IFD 258 ignites and monitors directly ignited industrial gas burners of unlimited capacity.
- As a result of its fully electronic design it reacts quickly to various process requirements and is therefore also suitable for frequent cycling operation.
- It can be used for atmospheric burners or forced draught burners in multiple burner applications
- Where a central control system is used for pre-purge and for monitoring.
- The burners may be modulating or stagecontrolled.
- The automatic burner control is suitable for operation in grounded and ungrounded systems.
- The program status and the level of the flame signal can be read directly from the unit.
- The switch-off threshold can be set using a potentiometer.
- The behaviour in the event of flame failure during operation can be selected using a switch.
- Either an immediate fault lock-out or a restart occurs.
- Control: On/Off
- Gas valve and air valve are activated simultaneously.
- The burner is ignited and monitored by a single electrode.
- In the event of a flame failure, an immediate fault lock-out occurs.
- Control: On/Off or On/High/Low/Off
- The burner BIO/BIC starts at low-fire rate.
- Once the normal operating state is reached
- The automatic burner control unit for continuous
- Operation IFD 258 will release control.
- The PLC can now pulse the air solenoid valve
- VRR in order to control the capacity between high and low fire.
- Control: On/Off/continuous
- The PLC uses the actuator IC 20 to move the air butterfly valve BVA to ignition position.
- The burner BIO/BIC starts at low-fire rate.
- Once the normal operating state is reached
- The PLC uses the actuator IC 20 and the air butterfly valve BVA to control the burner capacity.
- 200 V AC, -15/+10%, 50/60 Hz
- 120 V AC, -15/+10%, 50/60 Hz
- 100 V AC, -15/+10%, 50/60 Hz
- 230 V AC, -15/+10%, 50/60 Hz